3-Phase Reactors
Line/Load Reactors

Product Overview

Harmonic Compensated and IGBT Compatible
  • Increase Drive System Reliability
  • Filter Power Line Disturbances
  • Reduce Harmonics
  • Reduce Surge Currents
  • Reduce dv/dt
  • Extend Transistor Life
  • Reduce Motor Noise and Temperature
  • Reduce Voltage Doubling Effects
  • Improve True Power Factor
  • Absorb Power Line Spikes
Line/Load Reactors
Quick Links

Product Overview
Detailed Product Data
Selection Tables
Specification Table
Application Notes
Declaration of Conformity
Technical User Manuals


BENEFITS OF USING LINE/LOAD REACTORS

Guard-AC line/load reactors help keep your equipment running longer by absorbing many of the power line disturbances which otherwise damage or shut down your inverters, variable speed controllers, or other sensitive equipment. They are the modern technology solution to inverter and drive application problems. Guard-AC reactors are harmonic compensated and IGBT protected to assure optimum performance in the presence of harmonics. They are very effective at reducing harmonics produced by inverters and drives, and in most cases will help you to meet IEEE 519. Use our harmonic compensated reactors on either the input or output of an adjustable speed drive/inverter. There is no need to derate our "harmonic compensated" reactors for harmonics.

  • Protect Motors from Long Lead Effects
  • Reduce Output Voltage dv/dt
  • Virtually Eliminate Nuisance Tripping
  • Extend Semiconductor Life
  • Reduce Harmonic Distortion
  • Reduce Surge Currents
  • Reduce Motor Temperature
  • Reduce Motor Audible Noise
  • Improve True Power Factor
  • Helps Meet IEEE 519 or EN 61000-3-4
Agency Approvals

Guard-AC reactors are manufactured to the exacting standards of MIL-I-45208, VDE-0550, are UL recognized and CSA certified. All UL approvals are for USA and Canada.
· CSA File #LR29753, open units up to 2400A
· UL-508 File #E180243, open and enclosed up to 2400A
All higher current reactors offer UL recognized insulation systems and construction.



Impedance Ratings

3% impedance reactors are typically sufficient to absorb power line spikes and motor current surges. They will prevent nuisance tripping of drives or circuit breakers in most applications.

5% impedance reactors are best for reducing harmonic currents and frequencies. Use them when you must comply with IEEE 519, to reduce motor operating temperature, or to reduce motor noise.


% Impedance =[{I<sub>(50/60 Hz fundamental)</sub>*2*pi*f*L*SQRT(3)}/{V<sub>(L-L)</sub>}]*100

NOTE: The actual effective impedance of the reactor changes with actual fundamental current.




Back to top


Form #1141G



WORLD HEADQUARTERS
W147 N9525 Held Drive
P.O. Box 9013
Menomonee Falls, WI 53052 USA

Search
Subscribe



Line/Load Reactors Harmonic Filters RFI/EMI Filters DC Link Chokes
Surge Arrestors 3rd Harmonic Filters Motor Protection Filters

Home Technical Support News & Events Company Profile Contact Us Sitemap

Copyright © MTE Corporation | All Rights Reserved Privacy Statement